INCIDENTES CLÍNICOS ASSOCIADOS À SOBREUTILIZAÇÃO DE DISPOSITIVOS INVASIVOS EM TERAPIA INTENSIVA: UMA REVISÃO INTEGRATIVA

Arquivos de Ciências da Saúde da Unipar

Endereço:
Praça Mascarenha de Moraes, 4282 - UNIPAR - Zona III
Umuarama / PR
87502210
Site: https://www.revistas.unipar.br/index.php/saude
Telefone: (44) 3621-2828
ISSN: 1982-114X
Editor Chefe: Giuliana Zardeto
Início Publicação: 31/01/1997
Periodicidade: Quadrimestral
Área de Estudo: Ciências da Saúde

INCIDENTES CLÍNICOS ASSOCIADOS À SOBREUTILIZAÇÃO DE DISPOSITIVOS INVASIVOS EM TERAPIA INTENSIVA: UMA REVISÃO INTEGRATIVA

Ano: 2023 | Volume: 27 | Número: 6
Autores: Suelen Pessata Ferraz Flávia Giron Camerini Emanuelly Almeida da Silva Cintia Silva Fassarella Danielle de Mendonça Henrique Juliana Gerhardt Soares Fortunato
Autor Correspondente: Suelen Pessata Ferraz | [email protected]

Palavras-chave: Segurança do Paciente, Cuidados Críticos, Unidades de Terapia Intensiva, Patient Safety, Critical Care, Intensive Care Units, Seguridad del Paciente, Cuidados Críticos, Unidades de Cuidados Intensivos

Resumos Cadastrados

Resumo Português:

Objetivo: identificar as evidências disponíveis na literatura sobre os incidentes clínicos relacionados a sobreutilização de dispositivos invasivos em unidades de terapia intensiva (UTI). Método: revisão integrativa de literatura nas fontes de dados: PUBMED, EMBASE, CINAHL, WEB OF SCIENCE e LILACS. Foram incluídos estudos que abordem incidentes clínicos relacionados a sobreutilização de dispositivos assistenciais em Unidades de Terapia Intensiva. Foram excluídos estudos que não foram realizados em pacientesadultos; estudos que abordem dispositivos que não são manipulados pela equipe de enfermagem. Resultado: Foram incluídos para análise 15 estudos. Os principais incidentes clínicos relacionados ao tempo de uso dos dispositivos invasivos em UTI são as infecções. Os dispositivos predominantes para esta ocorrência foram: tubo orotraqueal, cateter vesical de demora e cateter venoso central. Tempo médio verificado para cada dispositivo: tubo orotraqueal considerando seis estudos foi de 7,7 dias; cateter vesical de demora foi de 8,2 dias baseado em sete estudos; cateter venoso central foi 12 dias, cálculo através de informações de oito estudos. Conclusão: a sobreutilização de dispositivos está relacionada a aumento do risco de incidentes, tendo como os principais evidenciados as infecções hospitalares.



Resumo Inglês:

Objective: to identify the evidence available in the literature on clinical incidents related to the overuse of invasive devices in intensive care units (ICU). Method: 3184Arquivos de Ciências da Saúde da UNIPAR,Umuarama, v.27, n.6, p.3183-3198, 2023. ISSN 1982-114Xintegrative literature review in the data sources: PUBMED, EMBASE, CINAHL, WEB OF SCIENCE and LILACS. Studies addressing clinical incidents related to overuse of assistive devices in Intensive Care Units were included. Studies that were not conducted in adult patients were excluded; studies that address devices that are not manipulated by the nursing staff. Results: Fifteen studies were included for analysis. The main clinical incidents related to the time of use of invasive devices in ICU are infections. The predominant devices for this occurrence were: orotracheal tube, indwelling urinary catheter and central venous catheter. Mean time verified for each device: orotracheal tube considering six studies was 7.7 days; indwelling urinary catheter was 8.2 days based on seven studies; central venous catheter was 12 days, calculated using information from eight studies. Conclusion: the overuse of devices is related to increased risk of incidents, with hospital-acquired infections as the main evidenced.



Resumo Espanhol:

Objetivo: identificar la evidencia disponible en la literatura sobre incidentes clínicos relacionados con el uso excesivo de dispositivos invasivos en las unidadesde cuidados intensivos (UCI). Método: revisión bibliográfica integradora en las fuentes de datos: PUBMED, EMBASE, CINAHL, WEB OF SCIENCE y LILACS. Se incluyeron los estudios que abordaban los incidentes clínicos relacionados con el uso excesivo de dispositivos de asistencia en las Unidades de Cuidados Intensivos. Se excluyeron los estudios que no se realizaron en pacientes adultos; los estudios que abordan dispositivos que no son manipulados por el equipo de enfermería. Resultados: Se incluyeron quince estudios para el análisis. Los principales incidentes clínicos relacionados con el tiempo de uso de dispositivos invasivos en UCI son las infecciones. Los dispositivos predominantes para esta incidencia fueron: tubo orotraqueal, sonda urinaria permanente y catéter venoso central. El tiempo medio verificado para cada dispositivo: tubo orotraqueal considerando seis estudios fue de 7,7 días; catéter urinario permanente fue de 8,2 días basado en siete estudios; catéter venoso central fue de 12 días, calculado utilizando la información de ocho estudios. Conclusión: el uso excesivo de dispositivos se relaciona con un mayor riesgo de incidentes, con las infecciones hospitalarias como principal evidencia.